Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(1): 89-96, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38071427

RESUMO

BACKGROUND: This article highlights four unique cases where rotational atherectomy (RA Rotapro, Boston Scientific) was used to cut and retrieve an entrapped coronary guidewire with parts extending into the aorta We discuss the technique and step by step approach to the retrieval procedure. CASE SUMMARY: Three of four cases described a guide wire entrapment in the right coronary artery (RCA), and one in the left anterior descending artery via retrograde route. In all cases the guide wire was intact within the intracoronary segment. In Case 1, the guide wire (Runthrough; Terumo) was entrapped in an acute marginal branch during chronic total occlusion (CTO) percutaneous coronary intervention. In Case 2, a whisper wire (Abbott) was entrapped during re-wiring of the right posterolateral branch through stent struts, the traction on the wire caused severe malformation of distal and proximal stents requiring second staged procedure to complete revascularization of the RCA CTO. In Case 3, a Runthrough wire was entrapped between two layers of stents and fractured at the proximal point with filaments extending into descending aorta. And in Case 4, a Pilot 200 (Abbott) wire was entrapped retrograde in the subintimal space via saphenous vein graft connection by tying a knot at the distal tip of the wire. In all four cases RA was used to successfully cut and remove the entrapped guide wires. DISCUSSION: Rotablation technique appears to be a safe and effective strategy for the management of entrapped coronary guidewire when conventional strategies fail.


Assuntos
Aterectomia Coronária , Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Aterectomia Coronária/métodos , Angiografia Coronária , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Oclusão Coronária/terapia , Oclusão Coronária/cirurgia , Stents , Doença Crônica
2.
Heliyon ; 4(3): e00585, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29862348

RESUMO

Heating a mixture of boron (impurities: carbon ∼ B50C2, boric acid - H3BO3) and tantalum (Ta) powders in nitrogen flow in a xenon high-flux optical furnace was performed. As-received powder composed of h-BN, H3BO3, TaB2, B9H11 and a number of other phases including ß-rhombohedral boron, apparently, heavily doped with Ta. FT-IR examination of any sample of the material reveals the complicated vibration spectrum containing, in particular, an absorption band near 2260 cm-1. The shapes of these bands are different for samples because powders were synthesized at different temperatures. Known, that in ß-rhombohedral boron lattice, there are nano-sized voids of different types, which allow an accommodation of single atoms or small groups of atoms. Theoretical calculations performed by the method of quasi-classical type yields the same value, 2260 cm-1, for the vibrations frequency of Ta atoms in D-type crystallographic voids in ß-rhombohedral boron lattice. Since, Ta atoms are known to prefer accommodation just in D-voids the experimentally detected bands can be identified with localized vibrations of Ta atoms.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...